Appendix IV: Mass spectrometry
Manufacturer: Hiden Analytical Ltd
Product name: QGA Atmospheric Gas Analysis System
Mass spectrometer
New this year: The new Hiden QGA Professional gas/vapor analysis software
Used for: Lab applications
Software: QGA Professional / MASsoft 7 Professional; may be used in other equipment, compatible with other manufacturers' equipment
Special features: Provides real-time continuous and quantitative analysis of gas mixtures comprising up to 16 species and is now available for operation with all Hiden gas analysis systems.
Suggested applications: High purity gas analysis, fermentation, fuel cells, gas production and storage, environmental monitoring
Primary benefits: Appearance potential mass spectrometry, fast response times – less than 300 ms, acquisition speed up to 500 measurements/s, Hiden QIC (quartz inert capillary) sampling interface samples from 100 mbar to 2 bar
Manufacturer: Markes International Ltd.
Product name: Select-eV
Mass spectrometer
New this year: New variable-energy electron ionization for GC–MS
Special features: No loss in sensitivity for fast and accurate compound identification
Used for: Lab analysis
Unique features: Source can change the energy of ionizing electrons; this allows the production of reference-quality electron ionization mass spectra with conventional full-fragmentation patterns. Energies can be varied anywhere from standard 70 eV down to 10 eV without loss in sensitivity; sometimes signal-to-noise ratios of many compounds are increased at lower energies.
Manufacturer: Microsaic Systems plc
Product name: 4000 MiD
Portable mass spectrometer
Used for: Lab, process, handheld analysis
Dimensions: 55 x 35 x 25 cm; weight: 32 kg
Measurement mode: Full scan (m/z 50-800), SIM and simultaneous SIM/fullscan
Software: Masscape, available as separate product, may be used in other equipment, compatible with other manufacturers' equipment.
Suggested applications: Mass detection for use in prep-, analytical-, flash- LC, reaction monitoring, flow chemistry, batch reaction online analysis, process monitoring.
Primary benefits: Deployability, everything fits inside a lab fume hood. You can take the mass spectrometer to the point of need.
Unique features: Smallest footprint single quadrupole MS, uses technology based on MEMS manufacturing, Fits in a standard fume hood, No external roughing pump needed, Integrated PC, remote operation supported, No A/C or sound-proofing required; deployability in a lab.
Manufacturer: Shimadzu
Product name: LCMS-8050
Triple-quadrupole LC–MS-MS system
New this year: Multiple reaction monitoring, 5-ms polarity switching, quantitative and qualitative analysis of multiple components.
Used for: Lab analysis
Primary benefits: 5 ms polarity switching, scan rate of 30,000 u/s, 555 MRM/s, heated ESI probe, high-efficiency CID cell maintains signal intensity
Unique features: Data browser and an automated MRM optimization routine. Application-specific method packages.
Manufacturer: Waters Corporation
Product name: Waters ionKey/MS System
Mass spectrometer
Used for: Lab analysis
Measurement mode: Microfluidic device and source for mass spectrometry.
Software: Available as separate product, 21CFR11 compliant, cGMP compliant, may be used in other equipment, compatible with other manufacturers' equipment
Suggested applications: Bioanalyses, pharmacokinetic studies, food safety and environmental analyses
Primary benefits: Enhanced sensitivity, plug and play nature: the Waters iKey separation device is designed so that all it takes is a few seconds for a scientist to insert it into the source of the mass spectrometer and with the turn of a key, make the fluidic and electric connections and lock it into place.
Unique features: The ionKey/MS System's iKey microfluidic separation device contains the fluidic connections, electronics, ESI interface, column heater, eCord Intelligent Chip technology and the 1.7-μm UPLC-grade particles packed inside a 150-μm i.d. channel. Stores the iKey device's dimensions, chemistry type, serial no., manufacturing and QC history on a unique eCord chip. Waters is offering several 1.7-μm UPLC grade particles for the ionKey/MS system available in 5 cm and 10 cm pathlengths: C18 BEH (Bridged Ethyl Hybrid) 300 Å, CSH (Charged Surface Hybrid), C18 BEH 130 Å
Getting accurate IR spectra on monolayer of molecules
April 18th 2024Creating uniform and repeatable monolayers is incredibly important for both scientific pursuits as well as the manufacturing of products in semiconductor, biotechnology, and. other industries. However, measuring monolayers and functionalized surfaces directly is. difficult, and many rely on a variety of characterization techniques that when used together can provide some degree of confidence. By combining non-contact atomic force microscopy (AFM) and IR spectroscopy, IR PiFM provides sensitive and accurate analysis of sub-monolayer of molecules without the concern of tip-sample cross contamination. Dr. Sung Park, Molecular Vista, joined Spectroscopy to provide insights on how IR PiFM can acquire IR signature of monolayer films due to its unique implementation.