Spectral measurements down to 153 nm can be achieved easily and economically with the high-sensitivity Maya2000 Pro with Extra-Deep-UV Option. Nitrogen purging of the spectrometer helps to mitigate water and oxygen absorption in the vacuum ultraviolet.
Spectral measurements down to 153 nm can be achieved easily and economically with the high-sensitivity Maya2000 Pro with Extra-Deep-UV Option. Nitrogen purging of the spectrometer helps to mitigate water and oxygen absorption in the vacuum ultraviolet.
A variety of materials have spectral signatures in the vacuum ultraviolet (VUV) spectral region, typically described as the region from 10 nm–200 nm (1,2), where air and water begin to absorb and require the use of a vacuum. VUV spectroscopy is useful for applications ranging from biomedicine to semiconductor testing. Because the spectral response of standard silicon charge-coupled device (CCD) detectors drops off rapidly at wavelengths as long as 400 nm, and because oxygen and water absorb in the VUV spectral band, maintaining sufficient signal outside a vacuum is not possible. Designing vacuum-compatible spectrometers to address these issues can be difficult and expensive. As a result, most commercially available VUV spectrometers require custom configuration and are too expensive and unwieldy for many common applications.
The Maya2000 Pro with Extra-Deep UV Option is poised to change that. The spectrometer features a 101.6-mm focal length optical bench with a compact crossed Czerny–Turner design and a back-thinned CCD detector that offers superior UV and VUV performance. To minimize signal attenuation inside the optical path, the spectrometer bench is purged with nitrogen, achieving a robust signal for VUV experiments at wavelengths as low as 153 nm (testing performed at NIST independently validated similar results at VUV wavelengths).
To test performance, we started with a Maya2000 Pro configured with a high resolution, UV-enhanced 2400 g/mm holographic diffraction grating and a 5-μm slit. The back-thinned detector (Hamamatsu S10420-1106) features a peak quantum efficiency of 75%, with UV quantum efficiencies as high as 50%. A custom magnesium fluoride (MgF2) glass window is placed over the detector for improved transmission over VUV wavelengths.
The test sample for the experiment was a VUV deuterium lamp with a VUV-grade optical window, coupled directly to the spectrometer. We enclosed the source and spectrometer and purged the region with standard laboratory-grade nitrogen.
Integration time for the measurement was 50 ms. The resultant emission spectrum shows sharply defined spectral peaks at wavelengths as low as 153 nm, with a strong central peak around 161 nm (Figure 1). The system operated with a spectral resolution of 0.1 nm and a signal-to-noise ratio of 450:1.
Figure 1: Emission spectrum of a VUV deuterium lamp shows clearly defined peaks, with good signal-to-noise performance and 0.1 nm (FWHM) optical resolution.
We have also used the system to measure a solution containing carbon, hydrogen/deuterium, nitrogen, oxygen, sulfur, chlorine, bromine, silicon and fluorine chromatographically separated into a column and placed in a vacuum chamber with a helium plasma mixture. VUV spectral features were clearly apparent in the spectrum, suggesting a wide variety of short-wavelength applications is achievable.
The results demonstrate that the reliable and economical Maya2000 Pro can be easily extended to VUV applications. Current work is focusing on studying different types of samples and pushing the spectral range to lower wavelengths.
(1) Wikipedia, http://en.wikipedia.org/wiki/Ultraviolet Website covers VUV under larger section on ultraviolet light.
(2) H. Horspool, F. Lenci, CRC Handbook of Organic Photochemistry and Photobiology (CRC Press, 2003).
Ocean Optics Inc.
830 Douglas Ave.
Dunedin, FL 34698
Tel. +1-727-733-2447, Fax +1-727-733-3962
Single Cell and Microplastic Analysis by ICP-MS with Automated Micro-Flow Sample Introduction
April 25th 2024Single cell ICP-MS (scICP-MS) is increasingly seen as a powerful and fast tool for the measurement of elements in individual cells, mainly due to the high sensitivity and selectivity of ICP-MS. Analysis is performed in the same way as single nanoparticle (spICP-MS) analysis, which has become a well-established technique for the analysis of nanoparticles and particles.
Hot News on Agilent LDIR, New Developments, and Future Perspective
April 25th 2024Watch this video featuring Darren Robey and Dr. Wesam Alwan from Agilent Technologies to gain insights into the future trends shaping microplastics research and the challenges of their characterization. Discover the essential components necessary for accurate microplastics analysis and learn how the Agilent 8700 LDIR system addresses these challenges. Offering rapid and precise analysis capabilities, along with easy sample preparation methods that minimize contamination, the Agilent 8700 LDIR system is at the forefront of advancing microplastics research.
Accurate and robust analysis of challenging environmental samples for regulatory compliance
April 25th 2024This application note discusses how the adverse effects of sample matrix can be circumvented with an analytical workflow that includes robust ICP-MS instrumentation offering comprehensive yet simplified analysis of samples containing high dissolved solids such as soil digests, wastewater and solid wastes. The data presented in this application note was generated over 12 hours with over 160 samples covering soil extracts and a variety of water samples.
Analysis of drinking water in compliance with EPA Method 200.8, Revision 5.4
April 25th 2024This application note describes the analytical workflow developed for the analysis of water samples over an extended period using the latest innovations in ICP-MS instrumentation. The innovations specifically highlighted in this app note are the next generation Argon Gas Dilution accessory, which simplifies the analysis of high matrix samples allowing direct analysis without prior manual diution; the HAWK consumables and maintenance assistant within the Qtegra ISDS software; the new Easy-click compact (ECC) peristaltic pump; and the new Thermo Scientific autosampler, the iSC-65 autosampler.