With gas and diesel fuel prices rising, there is an increasing need to monitor online quality control and blending mixtures. The benefits include improved accuracy in blending mixtures, solid state reliability, lifetime calibration and fraud avoidance.
With gas and diesel fuel prices rising, there is an increasing need to monitor online quality control and blending mixtures. The benefits include improved accuracy in blending mixtures, solid state reliability, lifetime calibration and fraud avoidance.
Figure 1
BaySpec is now delivering a compact, robust, affordable NIR Spectrometer engine ideal for OEM integration into fuel analyzer applications. The SuperGamut™ features excellent wavelength accuracy and repeatability at a low cost of ownership.
BaySpec's SuperGamut™ Series NIR Spectral Engines solve today's challenges through the application of proprietary Volume Phase Grating (VPG™) technology offering for the first time instrumentation manufacturers the features they need:
The SuperGamut™ Series was born out the telecommunication markets' "boom and bust", which produced an array of components and technologies, such as, revolutionary Volume Phase Gratings (VPG®), high speed electronic chips, reliable low cost light source and high speed NIR photo-detectors. Collectively, they enable the dream of a low-cost, yet highly accurate spectral device. Out of the ashes comes new growth.
SuperGamut™ Series instruments yield high spectral resolution and high optical throughputs under harsh environmental conditions over a broad NIR 800–2500 nm range at attractive total costs of ownership. Both reflectance and transmission modes of spectroscopic measurements and process applications are supported.
Customers in NIR spectroscopy and biomedical industries are now benefiting and building systems to meet the world's current optical system challenges.
BaySpec, Inc.
101 Hammond Avenue
Fremont, CA 94539
Tel. (510) 661-2008, Fax (510) 661-2009
Single Cell and Microplastic Analysis by ICP-MS with Automated Micro-Flow Sample Introduction
April 25th 2024Single cell ICP-MS (scICP-MS) is increasingly seen as a powerful and fast tool for the measurement of elements in individual cells, mainly due to the high sensitivity and selectivity of ICP-MS. Analysis is performed in the same way as single nanoparticle (spICP-MS) analysis, which has become a well-established technique for the analysis of nanoparticles and particles.
Hot News on Agilent LDIR, New Developments, and Future Perspective
April 25th 2024Watch this video featuring Darren Robey and Dr. Wesam Alwan from Agilent Technologies to gain insights into the future trends shaping microplastics research and the challenges of their characterization. Discover the essential components necessary for accurate microplastics analysis and learn how the Agilent 8700 LDIR system addresses these challenges. Offering rapid and precise analysis capabilities, along with easy sample preparation methods that minimize contamination, the Agilent 8700 LDIR system is at the forefront of advancing microplastics research.
Accurate and robust analysis of challenging environmental samples for regulatory compliance
April 25th 2024This application note discusses how the adverse effects of sample matrix can be circumvented with an analytical workflow that includes robust ICP-MS instrumentation offering comprehensive yet simplified analysis of samples containing high dissolved solids such as soil digests, wastewater and solid wastes. The data presented in this application note was generated over 12 hours with over 160 samples covering soil extracts and a variety of water samples.
Analysis of drinking water in compliance with EPA Method 200.8, Revision 5.4
April 25th 2024This application note describes the analytical workflow developed for the analysis of water samples over an extended period using the latest innovations in ICP-MS instrumentation. The innovations specifically highlighted in this app note are the next generation Argon Gas Dilution accessory, which simplifies the analysis of high matrix samples allowing direct analysis without prior manual diution; the HAWK consumables and maintenance assistant within the Qtegra ISDS software; the new Easy-click compact (ECC) peristaltic pump; and the new Thermo Scientific autosampler, the iSC-65 autosampler.