Carbon Quantum Dots Tested for Hypochlorite Detection and Cell Imaging

Author(s)Aaron Acevedo

In a study led by scientists from Northwest University in Xi’an, China, carbon quantum dots were tested on how well they can detect hypochlorite and aid in cellular imaging.

In a study led by scientists from Northwest University in Xi’an, China, carbon quantum dots were tested on how well they can detect hypochlorite and aid in cellular imaging (1). The findings were published in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy.

Hypochlorite (ClO-) is seen as an important reactive oxygen species that helps in different physiological and pathological processes within organisms. It can be used as a disinfectant and preservative for environmental sanitization and food preservation. Unfortunately, excessive ClO- can disturb redox balances and cause severe threats to human health, like respiratory irritation, lung damage, atherosclerosis, and cancer. This has led to a need for accurate and sensitive ClO- concentration monitoring techniques, especially so regarding the fields of life sciences, food, and the environment.

There are various methods for analyzing ClO-, including high performance liquid chromatography (HPLC), surface-enhanced Raman scattering, colorimetry, and fluorescence methods. Of the above methods, fluorescence and colorimetry have shown high accessibility, easy preparation, non-invasive nature, high sensitivity, and good comparability for bio-samples. This led the scientists to choose dual-mode methods for potential and application prospects for analysis and detection.

As part of the experiment, bright green, fluorescent carbon quantum dots (G-CQDs) were synthesized using a one-step hydrothermal method, which has citric acid and acriflavine precursors. Carbon dots (CDs) are crystalline and “zero-dimensional” carbon nanomaterials that have gained widespread attention; green CDs are specifically synthesized from renewable biomass, such as plants and other organic biomaterials (2).

Read More: Green Carbon Dots: Synthesis, Characterization, Properties and Biomedical Applications

Multiple characterization procedures were used throughout this experiment. The morphology and size of G-CQDs were measured by transmission electron microscopy (TEM), while Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), and zeta potential characterization assisted in helping the G-CQDs illustrate a significant amount of uniformly dispersed –NH2 and –OH on the surface. The fluorescence and colorimetric analysis helped in displaying a wide linear range and a low detection limit response to ClO-.

After the main part of the experiment, G-CQDs were applied for visualizing and quantitively detecting ClO- in drinking water samples, with the results showing a satisfactory recovery rate. Additionally, the dots showed good water solubility, optical stability, and optimal biocompatibility, all of which foreshadow a promising analysis approach in cell imaging and ClO- detection in living cells. This experiment highlighted the benefits and potential of G-CQDs, showing their capabilities in ClO--associated disease prevention and early clinical diagnosis.

References

(1) Chen, H.; Li, D.; Zheng, Y.; Wang, K.; et al. Construction of Optical Dual-Mode Sensing Platform Based on Green Emissive Carbon Quantum Dots for Effective Detection of ClO and Cellular Imaging. Spectrochim. Acta Part A: Mol. Biomol. Spectrosc. 2024, 309, 123733. DOI: https://doi.org/10.1016/j.saa.2023.123733

(2) Jing, H. H.; Bardakci, F.; Akgöl, S.; Kusat, K.; et al. Green Carbon Dots: Synthesis, Characterization, Properties and Biomedical Applications. J. Funct. Biomater. 2023, 14 (1), 27. DOI: https://doi.org/10.3390/jfb14010027


Related to this article

Infrared Reimagined: How FT-IR Spectroscopy Learned to Read Molecules, ©  Luis Eduardo  -chronicles-stock.adobe.com
FT-IR spectroscopy, long treated as a mature bench technique for confirming a carbonyl stretch or fingerprinting a polymer, has quietly become one of chemistry’s most versatile discovery engines: it now infers molecular structure straight from a spectrum without a reference library, resolves chemistry tens of nanometers wide, and screens a fingerstick of blood for disease in minutes. The last five years of published research show FT-IR moving from a confirmatory tool into a predictive, autonomous, and field-ready analytical platform.
FACSS 2026 Award Interviews ©  Erin -chronicles-stock.adobe.com
Eight FACSS award winners at SciX 2026, One LIBS trailblazer. Forty-eight questions. And not one of them is a softball. Award season in spectroscopy usually means polite applause, a plaque, and a photo. We're not completely interested only in the award sessions. The eight scientists honored at SciX 2026 in Sparks, Nevada, along with LIBS researcher Alessandro De Giacomo, are pushing Raman into operating rooms, flying LIBS on drones, reading chemistry off Mars, and tracing toxic metals downwind of industrial sites. Their work makes big claims. In the coming days, Spectroscopy will sit down with eight of these researchers and ask whether those claims hold up. The interviews that follow won't just celebrate. They'll press on the gaps between simulation and experiment, between the lab bench and the clinic, and between a clever paper and an instrument someone will actually buy and use.
Spectral Frontiers: Past the Diffraction Limit (FT-IR Spectroscopy)
Fourier-transform infrared (FT-IR) spectroscopy, long the workhorse of molecular fingerprinting, is being reinvented by photothermal detection schemes and quantum cascade laser (QCL) sources that push spatial resolution and analysis speed far beyond classical dispersive and interferometric limits. New instrumentation such as optical photothermal infrared (O-PTIR) microscopy and laser direct infrared (LDIR) chemical imaging is enabling sub-micron, label-free chemical mapping of biological, environmental, and pharmaceutical samples. This article reviews the latest FT-IR-adjacent technologies, recent patents, and research driving the field, featuring perspectives from the scientists and instrument developers advancing the technique.