Scientists from Duke University in Durham, North Carolina recently tested a surface-enhanced Raman scattering (SERS) spectroscopy system for detecting the SARS-CoV-2 virus. Their findings were published in Analytical Chemistry (1).
Coronavirus or Flu virus - Microbiology And Virology Concept | Image Credit: © Feydzhet Shabanov - stock.adobe.com
The COVID-19 pandemic caused an unprecedented need for rapid, sensitive, and cost-effective point-of-care diagnostic tests to prevent and mitigate the spread of the SARS-CoV-2 virus. Spectroscopy techniques can be used to detect the virus, protecting against the disease, and helping to screening for long COVID. For example, a study out of the Federal University of Sao Francisco Valley in Pernambuco, Brazil tested using visible or near-infrared (Vis-NIR) spectroscopy and machine learning algorithms to detect SARS-CoV-2 (2). Additionally, spectroscopy’s use to detect COVID-19 has been a hot topic at conferences. At SPIE Photonics West 2024 in TK PLACE, for example, Boris Mizaikoff of the University of Ulm discussed using breath analysis with used medical/N95 masks to detect long COVID-19 in patients. “Every time we put on a mask, we’re inhaling air, which means we’re trapping species from the outside world on the outside of the mask. When we’re exhaling, the inside [of the mask] is trapping everything we’re exhaling,” he said when explaining the sentiment behind this research (3).
Read More: Detecting Covid-19 Using Visible or Near-Infrared Spectroscopy and Machine Learning
In this study, the scientists demonstrated an advanced lateral flow immunoassay (LFIA) platform with dual-functional (colorimetric and surface-enhanced Raman scattering [SERS]) detection of the spike 1 (S1) protein of SARS-CoV-2. The nanosensor was integrated with a specially designed core–gap–shell morphology, made of a gold shell decorated with external nanospheres (with the structure being referred to as a gold nanocrown [GNC]). This structure was also labeled with a Raman reporter molecule of 1,3,3,1′,3′,3′-hexamethyl-2,2′-indotricarbocyanine iodide (HITC), so that a strong colorimetric signal and an enhanced SERS signal could be produced.
Read More: Screening for Long COVID Using Exhaled Breath Analysis
Among the different plasmonics-active GNC nanostructures, it was found that the GNC-2 morphology, which has a shell decorated with an optimum number and size of nanospheres, produces an intense dark-blue colorimetric signal and ultrahigh SERS signals. The limit of detection (LOD) of the S1 protein via colorimetric detection LFIA was determined to be 91.24 pg/mL. Compared to the SERS LFIA method, the LOD was found to be over three orders of magnitude lower at 57.21 fg/mL. Additionally, the performance of the GNC-2 nanosensor was analyzed regarding the direct analysis of the S1 protein spiked in saliva samples, albeit without prior sample pretreatment. With this approach, using SERS-based plasmonics-enhanced LFIA, the LOD was found to be as low as 39.65 fg/mL; these findings indicate ultrahigh detection sensitivity. With these findings, the scientists found that their GNC nanosensor exhibited excellent sensitivity, reproducibility, and rapid detection of the SARS-CoV-2 S1 protein. This all demonstrates the technique to have excellent potential as a point-of-care platform for the early detection of respiratory virus infections.
(1) Atta, S.; Zhao, Y.; Li, J. Q.; Vo-Dinh, T. Dual-Modal Colorimetric and Surface-Enhanced Raman Scattering (SERS)-Based Lateral Flow Immunoassay for Ultrasensitive Detection of SARS-CoV-2 Using a Plasmonic Gold Nanocrown. Anal. Chem. 2024, 96 (12), 4783–4790. DOI: 10.1021/acs.analchem.3c04361
(2) Acevedo, A. Detecting Covid-19 Using Visible or Near-Infrared Spectroscopy and Machine Learning. MJH Life Sciences 2023. https://www.spectroscopyonline.com/view/detecting-covid-19-using-visible-or-near-infrared-spectroscopy-and-machine-learning (accessed 2024-4-25)
(3) Acevedo, A. Screening for Long COVID Using Exhaled Breath Analysis. MJH Life Sciences 2024. https://www.spectroscopyonline.com/view/screening-for-long-covid-using-exhaled-breath-analysis (accessed 2024-4-25)
AI-Powered SERS Spectroscopy Breakthrough Boosts Safety of Medicinal Food Products
April 16th 2025A new deep learning-enhanced spectroscopic platform—SERSome—developed by researchers in China and Finland, identifies medicinal and edible homologs (MEHs) with 98% accuracy. This innovation could revolutionize safety and quality control in the growing MEH market.
New Raman Spectroscopy Method Enhances Real-Time Monitoring Across Fermentation Processes
April 15th 2025Researchers at Delft University of Technology have developed a novel method using single compound spectra to enhance the transferability and accuracy of Raman spectroscopy models for real-time fermentation monitoring.
Nanometer-Scale Studies Using Tip Enhanced Raman Spectroscopy
February 8th 2013Volker Deckert, the winner of the 2013 Charles Mann Award, is advancing the use of tip enhanced Raman spectroscopy (TERS) to push the lateral resolution of vibrational spectroscopy well below the Abbe limit, to achieve single-molecule sensitivity. Because the tip can be moved with sub-nanometer precision, structural information with unmatched spatial resolution can be achieved without the need of specific labels.