Using Multivariate Curve Resolution to Identify the Evolved Gases Created During a TGA-IR Experiment
September 1st 2014Thermal decomposition provides valuable information about the chemical composition of a material. Although thermal gravimetric analysis (TGA) measures small weight losses during a heating ramp, it cannot identify the chemicals corresponding to the weight loss.
Miniature Spectrometers for Narrowband Laser Characterization
September 1st 2014Used everywhere from bar code scanners to sophisticated single-molecule microscopes, lasers are powerful and cost-effective light sources for applications spanning basic research to consumer entertainment.
Simultaneous Single Reaction Chamber Microwave Digestion of Mixed-Consumer Products
September 1st 2014Milestone's UltraWAVE microwave digestion system with single reaction chamber (SRC) technology, enables the simultaneous digestion of up of to 22 different sample types and chemistries at temperatures and pressures as high as 300 ?C and 199 bar.
Using Infrared Spectroscopy for Real-Time Diagnostics During Brain Surgery
September 1st 2014What if the decisions neurosurgeons make during surgery - such as about how much tissue to remove - could be guided by immediate results from spectroscopic methods? A number of spectroscopy researchers are seeking to advance methods to make that both possible and practical.
Chemical Analysis of Microscopic Fluorescent Materials by Dispersive 1064 Raman System
September 1st 2014Raman measurement on microscopic inclusions in fluorescent materials requires the ability to measure in small volumes, excellent throughput, and long wavelength excitation such as 1064 nm for fluorescence reduction.
Using the Full Spectrum for Raman: From UV to NIR
The "inelastic scattering of light," or Raman effect, was observed in practice for the first time in 1928 by C.V. Raman for which he was awarded the Nobel Prize in 1930.
Determination of Sodium Lauryl Sulfate and Sodium Laureth Sulfate in Commercial Body Care Products
September 1st 2014A method for quantifying the percent sulfate associated with sodium lauryl sulfate (also referred to as sodium dodecyl sulfate) and sodium laureth sulfate (also referred to as sodium lauryl ether sulfate) found in commonly used commercial body care products using FT-IR attenuated total reflectance (ATR) spectroscopy is outlined.
X-ray Diffraction and Fluorescence Spectroscopy Analysis of Sm3+ in Lithium Calcium Silicate
September 1st 2014Luminescence materials are important for modern technology because of their ability to convert electromagnetic radiation (that is, ultraviolet [UV] and infrared [IR] light) into visible light (1).
Lanthanide Series Investigations with TSI LIBS Desktop Analyzer
September 1st 2014The lanthanide series is a series of metallic elements, with atomic numbers 58 through 71, which are - in order of increasing atomic number - cerium, praseodymium, neodymium, promethium, samarium, europium, gadolinium, terbium, dysprosium, holmium, erbium, thulium, ytterbium, and lutetium.