Appendix VII: NMR

Appendix VII: NMR

Manufacturer: Magritek

Product name: Spinsolve Carbon

Benchtop NMR spectrometer

New this year: Capability to offer H, F, and C analysis; the first benchtop NMR spectrometer to offer 13C NMR spectroscopy. Also provides advanced 2D NMR experiments such as HMQC, HETCOR, COSY, and JRES.

Used for: Laboratory analysis and process applications

Dimensions: 58 X 43 X 40 cm

Weight: 55 kg

Measurement mode: NMR

Software: Supplied with MNova data processing software from Mestrelab

Suggested applications: Pharmaceutical/drug development/QA; reaction monitoring; synthetic chemistry; education/teaching

Unique features: Benchtop, cryo free, good resolution even at low MHz frequencies

Manufacturer: Magritek

Product name: Spinsolve Phosphorous

Benchtop NMR spectrometer

New this year: The first benchtop NMR spectrometer to offer H, F, C, and P analysis. Also provides advanced 2D NMR experiments such as COSY, and JRES.

Used for: Laboratory analysis and process applications

Dimensions: 58 X 43 X 40 cm

Weight: 55 kg

Measurement mode: NMR

Software: Supplied with MNova data processing software from Mestrelab

Suggested applications: Adding phosphorous capability opens new applications in petrochemicals – oils and additives.

Unique features: Benchtop, cryo free, good resolution even at low MHz frequencies

Manufacturer: Nanalysis Corp.

Product name: NMReady 60

NMR spectrometer

New this year: Can switch on the fly between proton and fluorine NMR

Used for: Lab, process analysis

Dimensions: 27 x 28 x 48 cm (H x W x L)

Weight: 50 lb

Measurement mode: NMR

Specialty accessory description: NMR tube warmers

Special Features: Portable between labs, built-in touch screen computer, networked

Software: May be used in other equipment

Suggested applications: Oil and gas, chemical, pharma, biotech, food processing

Primary benefits: Easy to use, no cryogens (low maintenance), fits on the benchtop, touch-screen interface, uses standard 5mm tubes, plugs in standard wall power, network capable, excellent as a training tool, exports data in standard JDX format, 60 MHz with better than 2 Hz resolution

Unique features: Only all-in-one benchtop NMR spectrometer, data acquisition and processing simple, even for non-experts, offers spectroscopic resolution at the fractions of the size, cost and maintenance of current instrumentation

Manufacturer: Thermo Fisher Scientific

Product name: picoSpin 80

NMR spectrometer

Suggested applications: Pharma, chemical, and academia

Primary benefits: The benefits include: temperature-controlled magnet that does not require liquid cryogens; lightweight, portable design, easy-to-operate fluid capillary system that dispenses with NMR tubes, other consumables.

Articles in this issue

Related to this article

Monitoring Sugar Consumption and Ethanol Production During Yeast Fermentation Using a Raman Plate Reader and Multivariate Analysis
This column shows that a Raman plate reader paired with partial least squares regression can simultaneously quantify glucose, fructose, sucrose, and ethanol in yeast fermentation samples, using turbidity-matched calibration standards to correct for yeast-induced turbidity, and offers a rapid, label-free, high-throughput method for tracking sugar consumption and ethanol production in strain screening, media optimization, and process development.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.
Healthcare administrator reviewing an insurance policy schedule with a stethoscope on a clipboard, health insurance coverage, medical underwriting, prior authorization, and patient claims processing. | Image Credit: Joi_studio - stock.adobe.com
In a SciX interview, Marc Porter covered a lot of ground, from a student-driven pivot into immunoassays to a baseball analogy for Stokes and anti-Stokes scattering, and shares the open questions he is still chasing.
Ingots of pure copper or pink gold on a black background. | Image Credit: Phawat - stock.adobe.com
At SciX, Kevin Wilkinson of the Universite de Montreal explains how faster data acquisition and new software have cut analysis time and how a particle’s chemical composition can link arsenic-bearing emissions back to a copper refinery’s processes.
Spectral Frontiers: Seeing the Unseeable Microspectroscopy
Microspectroscopy, the marriage of spectroscopic chemical identification with microscopic spatial resolution, has advanced from Perkin-Elmer's first commercial infrared microspectrometer in 1953 to today's nanoscale AFM-IR probes, synchrotron-brightness infrared beamlines, and compact hyperspectral tissue imaging devices being developed for AI-assisted cancer detection.