Analyzing the effect of UV LED modules on disinfecting ballast water using UV–vis spectroscopy.
Analyzing the effect of UV LED modules on disinfecting ballast water using UV–vis spectroscopy.
Ballast water is seawater that fills a ship to maintain its balance. Annually, about 10 billion tons of ballast water with organisms such as planktons, germs, and bacteria is being transported around the world, and they cause diseases and contamination of marine ecology. UV treatment has the advantage of having no remaining toxic and disinfection by products (DBPs). Selective monochromatic wavelengths can be applied in the UV. Besides this UV LED modules have a low power consumption rate and only a 10~100 (mA) applied current.
Therefore, UV LED modules were designed and fabricated to analyze the disinfection characteristics of UV LED with wavelengths of 255, 265, and 280 nm on phytoplankton such as Tetraselmis sp.
Spectrum Analysis
To analyze the optical spectrum characteristics of the fabricated UV LED modules, a spectrometer (Avaspec-3648, Avantes) was used.
Figure 1: Avantes spectrum of the UV LED modules.
The UV LED modules that were used in the experiment showed peak wavelengths at 255, 265, and 280 nm and approximately 10 nm full widths at half maximum (FWHM). Because the UV LED had the characteristics of a monochromatic wavelength that does not show its spectrum in ranges except for those mentioned above, selective UV irradiation was possible (1).
The disinfection rates of the Tetraselmis sp. showed to be in accordance with the energy that was irradiated onto each UV LED module. The results show that the more the energy that was irradiated, the higher the disinfection rate was.
As a result, in the case of the Tetraselmis sp., the valid disinfection area was formed within the wavelength of the UV-C, and especially the highest disinfection rate occurred between 260 nm and 270 nm.
Figure 2: Shape of the Tetraselmis sp. before and after the UV treatment. While the Tetraselmis sp. clearly showed a round cell membrane before the UV treatment, the shape of the cell membrane was transformed after the UV treatment (2).
Figure 2 shows the shape of the Tetraselmis sp. before and after the UV treatment. While the Tetraselmis sp. clearly showed a round cell membrane before the UV treatment, the shape of the cell membrane was transformed after the UV treatment (2).
(1) Li Xiaojuan and Chen Cunshe, WSEAS Transactions on computers 8(2), 237–247 (2009).
(2) Xiaoli Zhou, Muqing Liu, Yong Qian, Hui Wang, and Shaolong Zhu, WSEAS Transactions on electronics 5(12), 457–467 (2008).
Avantes
9769 W. 119th Dr., Suite 4, Broomfield, CO 80021
tel. (303) 410-8668 or (866) 678-4248, fax (303) 410-8669
Website: www.avantes.com
Oligonucleotide Analysis in Pharmaceutical Quality Control
January 14th 2025Melting point determination using ultraviolet-visible (UV-Vis) spectrophotometry can be used as a sequence-specific method for identifying therapeutic oligonucleotides in pharmaceutical quality control. This method offers a simple, highly selective approach to differentiate between isomers and ensure the integrity of oligonucleotide active pharmaceutical ingredients (APIs) and drug products.
The Optical Properties of Solid Samples
January 14th 2025Transmittance and reflectance measurements, which are useful for estimating the effects of various physical processes, can include thermal treatments, ionizing radiation exposure, optical exposure, and mechanical treatments—on both crystals and thin films.
Streamlining Food & Feed Pre-Analytical Workflows for Metals and Fat Determination
January 8th 2025A focus on optimizing sample preparation in food and feed analysis can improve laboratory efficiency, data quality, and compliance with regulatory standards. Innovations like advanced microwave digestion and automated reagent handling can streamline workflows, improve safety, and ensure reliable analyses, ultimately supporting overall food safety.