Single reaction chamber microwave digestion enables a chemist to digest up to 15 different specialty chemical samples simultaneously at temperatures as high as 300 ?C, greatly simplifying the workflow while maintaining superior quality digestions.
Single reaction chamber microwave digestion enables a chemist to digest up to 15 different specialty chemical samples simultaneously at temperatures as high as 300 °C, greatly simplifying the workflow while maintaining superior quality digestions.
The class of "Specialty Chemicals" encompasses a wide variety of chemicals ranging from single chemical entities to complex formulations. While some of these chemicals are easy to prepare for trace metals analysis, many others require extremely high temperatures for complete digestion, which is difficult to achieve even with conventional closed vessel microwave systems. Often chemists have to complement microwave technology with traditional tools like hot plates and Paar bombs to digest the highly stable matrices which in turn have their own set of limitations — large acid requirements, contamination, acid handling challenges, lengthy digestions cycles, and exposure of chemists to acid fumes. Finally, although multiple samples can be digested in closed vessel microwaves simultaneously, samples of similar matrices need to be batched and run separately to ensure complete control over the system. This can severely hamper the productivity of a lab testing specialty chemicals, as a wide variety of sample matrices often require preparation.
Table I: Recovery data for ERM 681
Milestone's UltraWAVE SRC benchtop digestion system can digest up to 15 different samples simultaneously at temperatures and pressures as high as 300 °C and 199 bar. This high temperature and pressure capability enables a complete digestion of almost any specialty chemical that needs to be analyzed for trace metals. Samples can be directly weighed into disposable glass, autosampler type vials with the appropriate acid mixtures; no minimum acid quantity is required. Quartz and TFM vials can also be used depending on the user's application. This minimizes acid handling and transferring steps, which reduces errors due to contamination and the chemist's exposure to acids. It also completely eliminates the need to clean, assemble, and disassemble vessels used in conventional microwave systems.
Table II: Recovery data for CRM8112A
The reaction chamber was pre-pressurized to 40 bar to prevent the acids from boiling, which subsequently prevented cross-contamination and loss of volatiles. 15-position racks were used with disposable glass vials which were covered by loose fitting caps. This ensures pressure equilibrium on either side of the vial while preventing the condensation from the top of the chamber from dripping into the sample. 0.2g of ERM681 (low density polyethylene) and CRM8112A (ABS Resin) were simultaneously digested in 4 ml of 68% nitric acid. The samples were heated to 225 °C in 15 min and held at 225 °C for 15 min. The trace metals in the digested samples were analyzed using a PE Optima ICP-OES system.
The data shows excellent DLs and recoveries. No loss of volatile elements (like Hg) or cross contamination was observed. Due to higher sample capacity, use of disposable vials and faster cool down time, the UltraWAVE sample throughput is 2–3 times higher as compared to closed vessel microwave digestions. Its lower consumables costs, simple operation, and superior digestion quality make Milestone's UltraWAVE a perfect choice for specialty chemical's sample prep.
Milestone, Inc.
Controls Drive, Shelton, CT 06484
tel. (866) 995-5100, fax (203) 925-4241
Website: www.milestonesci.com
Testing Solutions for Metals and PFAS in Water
January 22nd 2025When it comes to water analysis, it can be challenging for labs to keep up with ever-changing testing regulations while also executing time-efficient, accurate, and risk-mitigating workflows. To ensure the safety of our water, there are a host of national and international regulators such as the US Environmental Protection Agency (EPA), World Health Organization (WHO), and the European Union (EU) that demand stringent testing methods for drinking water and wastewater. Those methods often call for fast implementation and lengthy processes, as well as high sensitivity and reliable instrumentation. This paper explains how your ICP-MS, ICP-OES, and LC-MS-MS workflows can be optimized for compliance with the latest requirements for water testing set by regulations like US EPA methods 200.8, 6010, 6020, and 537.1, along with ISO 17294-2. It will discuss the challenges faced by regulatory labs to meet requirements and present field-proven tips and tricks for simplified implementation and maximized uptime.
Practical Autodilution for ICP-MS and ICP-OES
January 20th 2025Gain insights into improving efficiency and accuracy in elemental analysis through automated dilution technology. Learn about the key capabilities of the Agilent ADS 2 system and its seamless integration with ICP-MS and ICP-OES workflows.
UV-Vis Spectroscopy: Exporting Your Measurement Out of the Instrument
January 20th 2025Optical fibers in ultraviolet-visible (UV-Vis) spectroscopy can enable measurements outside the traditional sample compartment. This paper details the components needed for fiber optic systems, such as couplers and probes, and reviews the performance of Agilent's Cary series instruments. It is crucial to choose the right fiber optic setup for a specific lab’s needs to ensure accurate and efficient measurements.