Application Notebook
Savillex's DST Acid Purification Systems are used by laboratories worldwide for the on-demand production of high purity acid for use with ICP-MS and other metals analysis techniques. Savillex recently expanded the product line with the new DST-4000, which is a high-throughput, fully-automated system capable of producing 4 L of high-purity acid at a time, completely unattended.
Figure 1: Savillex DST-4000.
The ultra-low detection limits of ICP-MS necessitate the use of high-purity grade acids for standards, sample dilutions, and, increasingly, even for sample digestion. Although commercially available bottled high-purity (10 ppt grade) acid is readily available, it costs up to 10 times more than trace metal (1 ppb) grade acid. Once opened, and during use, a bottle of high-purity acid can easily become contaminated due to airborne contamination or analyst error. For these reasons, many laboratories are producing their own high-purity acid using the Savillex DST-1000 Acid Purification System. The DST-1000 produces HNO3, HCl, and HF that is as good as or better than commercially available acid (Table I), is easy to use, has a small footprint, and can pay for itself in months, or even weeks, depending on the laboratory's acid needs.
Although in-laboratory production of high purity acid can easily be justified financially, some laboratories prefer to continue to purchase bottled high-purity acid. This is because there was no system that could either produce enough acid to meet their needs, or be operated completely unattended thus requiring additional labor. Recently, Savillex released the DST-4000. The quality of acid produced by the new DST-4000 is the same as the DST-1000, however the DST-4000 can produce 1 L of acid in 12 h-double the throughput of the DST-1000. In addition, its acid level sensor and auto-shutoff feature allows it to be run completely unattended. Acid (up to 4 L at a time) is simply added to the DST-4000 via the conveniently located front fill tube, the unit is switched on using the external controller, and the user walks away. High-purity acid is collected in a pair of 2 L Purillex™ PFA bottles, and the DST-4000 switches off automatically when the run is completed. The acid in the collection bottles is protected from the environment by specially designed closures, and ready for use when needed. The in-laboratory production of high-purity acid has never been easier or more convenient.
Savillex Corporation
10321 West 70th St., Eden Prairie, MN 55344-3446
tel. (952) 935-4100
Website: www.savillex.com
Best of the Week: AI and IoT for Pollution Monitoring, High Speed Laser MS
April 25th 2025Top articles published this week include a preview of our upcoming content series for National Space Day, a news story about air quality monitoring, and an announcement from Metrohm about their new Midwest office.
LIBS Illuminates the Hidden Health Risks of Indoor Welding and Soldering
April 23rd 2025A new dual-spectroscopy approach reveals real-time pollution threats in indoor workspaces. Chinese researchers have pioneered the use of laser-induced breakdown spectroscopy (LIBS) and aerosol mass spectrometry to uncover and monitor harmful heavy metal and dust emissions from soldering and welding in real-time. These complementary tools offer a fast, accurate means to evaluate air quality threats in industrial and indoor environments—where people spend most of their time.