Mixed-Batch Food Sample Microwave Digestion
April 15th 2016The Milestone UltraWAVE is a bench-top instrument that operates at very high pressures and temperatures, capable of processing large, dissimilar and difficult samples quickly, easily-all without batching. The data shown in this technical note demonstrates that the digestion of samples in the UltraWAVE results in uniformly high analytical data quality, making it the ideal solution for trace metals detection in food.
PeakFinderTM Fiber Optic Raman Video Probe
April 14th 2016BaySpec’s PeakFinderTM Raman video probe combines a flexible fiber optic probe with microscope objectives allowing sampling down to several microns. Combined with various benchtop Raman spectrometers, the Raman video probe is a unique micro-Raman system available in 532, 785 or 1064nm excitation and various microscope objectives offering unprecedented flexibility and versatility.
Portable Raman Spectroscopy in Archaeology and Art
April 14th 2016Raman spectroscopy is an important instrument in the arsenal of art conservators and archaeologists. This application note summarizes some recent literature on the selection of portable instruments in this field and also documents some successful work done utilizing background correction to elucidate the composition of some challenging green pigments.
Ancient and Modern Artwork Pigments Revealed by Fluorescence Spectroscopy
April 11th 2016Fluorescence spectroscopy is used to investigate museum specimen as a flexible and minimally invasive technique. The photo-physical properties of Egyptian and modern artwork pigments are presented in this application note.
Why Choose the new Thermo Scientific iCAP RQ ICP-MS for your lab?
March 25th 2016Introducing a new single quadrupole ICP-MS to the range of trace elemental analysis solutions offered by Thermo Scientific. To learn more, Spectroscopy Magazine talked with Shona McSheehy-Ducos, ICP-MS Product Manager, Thermo Fisher Scientific in Bremen, Germany.
New Ways of Automating Analysis in Confocal Raman Imaging
March 21st 2016Overcoming the boundary between user-friendliness and the ultimate capability in Raman Imaging is the key to effortlessly manage the image-acquisition and data evaluation at the highest lateral and spectral resolution. This executive summary will explore how the most intricate Raman Imaging experiments can be easily accomplished leading to a greatly improved data quality, ease of use and productivity.
Do You Know What is Protecting Your Telephone Screen?
March 18th 2016Optimization and follow up of manufacturing process of plastics films are easily achieved using Pulsed RF Glow Discharge Optical Emission Spectrometry. This technique allows the fast detection of defects and presence of contaminants.
SPRi / MALDI-MS Array Platform
March 18th 2016Combining SPRi technology with MALDI mass spectrometry on the same surface is a powerful approach for the analysis of biomolecular interactions, allowing measurement of biomolecular interactions by SPRi, and then detection of the retained ligands by MALDI mass spectrometry directly from the sensor surface.
Raman Spectroscopy of Pharmaceutical Ingredients Under Humidity Controlled Atmosphere
March 18th 2016Exposure to warm/humid conditions may cause pharmaceutical formulations to undergo change in hydration level, affecting properties and/or efficiency of the drug. Raman spectroscopy, with a temperature and humidity controller can mimic harsh conditions, monitor properties of ingredients and track modifications induced by environmental changes.
Dye-protein Binding Monitored in a Microliter Volume Using Time-resolved Fluorescence
March 18th 2016Time‐resolved Fluorescence can analyze potential health benefits from antioxidant activity of curcumin, found in turmeric. Curcuminoids, weakly fluorescent in aqueous solution, show quantum yield increases upon interaction with a protein, such as human serum albumin.
ParticleFinder – Automated Particle Location and Raman Analysis with LabSpec 6
March 18th 2016Locate particles, generate size/shape statistics, select particles based on size/shape, and acquire Raman spectra. Easily locate and identify particulate matter, including pharmaceutical materials, trace forensic evidence, geological rock/mineral particles, and airborne contaminants trapped on filters
Secondary Structure Analysis poly-L-glutamic Sodium Titration
March 17th 2016Since the function of a protein is closely related to its structure, the structural analysis of proteins and peptides is becoming increasingly important to assist in deciphering bioactivity. CD measurements are easy to obtain, and small sample volumes can be used. Additionally, conformational changes of proteins and peptides due to pH, temperature and external ligands can also be obtained.
Learn How UltraWAVE is Changing the Game for Metals Prep
March 14th 2016Patented UltraWAVE SRC technology goes beyond traditional digestion, offering greater capabilities for the most difficult sample types. High-performance stainless steel construction allows for higher pressures and temperatures, while disposable vessels eliminate the need to assemble, disassemble or clean between processing. Just as important, dissimilar samples can be processed simultaneously, saving time and money.
Enhanced Raman Reflection Spectroscopy for Process Analytical Technology
February 17th 2016A novel approach in Raman spectroscopy enables bulk material analysis without the need for specialized equipment. Enhanced Raman reflection can be integrated into current processes using available instrumentation, enabling real-time process measurement and control.