NIR Micro-Photoluminescence Characterisation of Single Semiconductor Quantum Wires
September 1st 2011Nanoscale structures (quantum dots and quantum wires) are being studied extensively with a view to building ever more exotic devices, such as more efficient lasers and LEDs, or quantum information processing components. One type of material under investigation consists of semiconductor quantum wires based on InAs.
Temperature Induced Changes in Clays Measured by Diamond ATR FT-IR Spectroscopy
September 1st 2011Increasing temperature can cause chemical changes, alter reaction rates, concentrate an aqueous sample, or evaporate a solvent. These transformations can be readily monitored by diamond ATR spectroscopy. This note explores the use of a diamond ATR to examine heat-induced changes in the clay.
Topographic Confocal Raman Imaging using True Surface Microscopy
September 1st 2011True surface microscopy for topographic confocal Raman imaging adds optical profilometer functionality to a highly sensitive confocal Raman microscope. Using this profilometer function, topographic scans of several square millimeters can be acquired, similar to a very large AFM topography image. This acquired large-area topography image can be used to trace the surface contours while acquiring a confocal Raman image.
The Orbis Micro-XRF Analyzer Series
September 1st 2011Building on more than 10 years of Micro-XRF experience, the Orbis spectrometer yields a system with excellent Micro-XRF capability while setting a new standard in analytical flexibility. The Orbis incorporates a unique motorized turret integrating video and X-ray optics allowing coaxial sample view and X-ray analysis. The turret can accommodate two additional collimators along with the X-ray optic for a total of three X-ray beam sizes to expand the Orbis analytical capabilities beyond traditional Micro-XRF analysis. Primary beam filters can be used with all spot sizes available on the turret to allow true XRF analytical capabilities in a micro-spot analysis. The working distance is increased to allow analysis over rougher sample topography without sacrificing signal intensity.
Trace Element Analysis of Heavy Metals in Pharmaceutical Materials
February 1st 2010One of the most common product safety-related analytical tests in the pharmaceutical industry (often referred to as a Limit Test) is the quantification of heavy metals or inorganics in all materials within a pharmaceutical product.
Applications of 1064 nm Dispersive Raman Systems in Biofuel Research
February 1st 2010BaySpec, Inc. has developed a complete line of 1064 nm excitation, dispersive Raman systems that offer maximum reduction in fluorescence interference from biological samples and thus making them very useful tools for biofuel research.