The list of acronyms in mass spectrometry published regularly here reflects the writings and conversations of mass spectrometrists, who use a variety of acronyms to describe particular experiments or applications. New applications, with new audiences, bring new technical jargon.
The list of acronyms in mass spectrometry published regularly here reflects the writings and conversations of mass spectrometrists, who use a variety of acronyms to describe particular experiments or applications. New applications, with new audiences, bring new technical jargon. Shorthand-speak becomes common, and practitioners in one subdiscipline become more isolated, even in conversation, from their colleagues in other areas. This isolation is magnified by a dynamic lexicon that is as complex as it is specialized. Instruments are described by acronyms, along with ionization methods, analysis methods, experimental protocols, and data interpretation and presentation schemes. An environmental mass spectrometrist assesses results from an SIM GC–MS BTEX analysis. A carbohydrate mass spectrometrist works with data from PSD MALDI TOF using DHB matrices. Proteomics folks debate MOWSE scores from high-throughput PMF, all part of an NDA. To each group, these terms reflect their own ROOMS. Researchers enjoy coining acronyms as much as the federal government, and our acronym-laden language can be equally intimidating. This compilation may aid in our translations, both to others as well as for ourselves.
Some acronyms are protected trademarks but might not be noted as such in the literature. Companies coin acronyms, words, and descriptive phrases with the same gleeful abandon as individual researchers. I have not included vendor-specific acronyms or trademarks unless they seem to have entered common use. I also have resisted the inclusion of terms that only appear to be acronyms, but which are either unduly contorted or capitalized for the sake of appearance. Inclusion of an acronym in this list is not an explicit endorsement of its use by the community; the nomenclators eventually make their judgments, but the community itself enforces a certain discipline. Immortality in the annals of science is not to be gained by coining a new acronym; a truly useful acronym quickly becomes so widely used that the originator often is forgotten. Our search for fame (not FAME) then, leaves us only with eponomy, a topic that has merited specific academic study, although not yet in the field of mass spectrometry. Lastly, do not confuse an acronym with a shorthand for a chemical formula, or shorthand for a structure. Acronyms that appear in reference titles cannot be deciphered in context, and so will appear in this compilation.
For some recent additions to the acronym list, a short description is provided, along with a recent (not necessarily the first) reference. These vignettes should encourage you to visit the reference given for a more complete description. Acronyms are listed here in alphabetical order. Most acronyms are composed of upper-case letters, but a few are traditionally given as sequences of lower-case letters, or a mixture, to the consternation of spell checkers, editors, and indexers everywhere. The debate between GC–MS and GC/MS was settled long ago, but the community today doesn't seem to remember how or why the decision was made. I resist the urge to revisit the arguments. If your favorite acronym or abbreviation is missing from the list, please contact me.
A Anion
ACMS Asilomar Conference on Mass Spectrometry
ADC Analog-to-digital converter
ADO Average dipole orientation
AE Appearance energy
AEI Associated Electric Industries, a past MS manufacturer
AGC Automatic gain control
AGHIS All-glass-heated-inlet system
AMS Accelerator mass spectrometry; Adolescent mass spectrometrists
amu atomic mass unit
AN Auger neutralization; Application note (in JASMS)
ANP 2-Amino-5-nitropyridine (a MALDI matrix)
ANZSMS Australia and New Zealand Society for Mass Spectrometry
AP Appearance potential; Atmospheric pressure
APCI Atmospheric pressure chemical ionization
API Atmospheric pressure ionization
APPI Atmospheric-pressure photoionization
ARMS Angle-resolved mass spectrometry
ASGDIMS Atmospheric-sampling glow discharge ionization mass spectrometry
ASMS American Society for Mass Spectrometry
ASTM American Society for the Testing of Materials
ATT 6-Aza-2-thiothymine (a MALDI matrix)
AVS Accelerating voltage scan; American Vacuum Society
B Magnetic sector mass analyzer, magnetic field; magnetic sector field strength or flux density
BAMS Bioaerosol mass spectrometry
Individual cells of airborne Bacillus are differentiated based upon the reproducible spectral differences observed after laser ionization. Both positive and negative ion mass spectra are measured in the range to about 200 Da. Instrumental considerations for method development for real- time air monitoring are described. See: D.P. Fergenson, M.E. Pitesky, H.J. Tobias, P.T. Steele, G.A. Czerwieniec, S.C. Russell, C.B. Lebrilla, J.M. Horn, K.R. Coffee, A. Srivastava, S.P. Pillai, M.T.P. Shih, H.L. Hall, A.J. Ramponi, J.T. Chang, R.G. Langlois, P.L. Estacio, R.T. Hadley, M. Frank, and E.E. Gard, Anal. Chem. 76, 373–378 (2004).
BAT Best anode temperature
BDE Bond dissociation energy
B/E Linked scan for product ions in MS-MS
B2E Linked scan for parent ions in MS-MS
BEoQ A reverse-geometry sector instrument followed by an octupole collision cell followed by a quadrupole mass filter
BEqQ A reverse-geometry sector instrument followed by a collision quadrupole followed by a quadrupole mass filter
BEMS Biomedical and Environmental Mass Spectrometry (a former MS journal)
BET Best emitter temperature
BIAMS™ Biomolecular interaction analysis mass spectrometry
BIRD Blackbody infrared radiative dissociation
BMS Biomedical Mass Spectrometry, Biological Mass Spectrometry
BNG Bradbury–Nelson gate
The use of the Bradbury–Nelson gate as an ion modulation device and encoder for an ion beam is described in conjunction with its use in a Hadamard-transform time-of-flight mass spectrometer. See: O.K. Yoon, I.A. Zuleta, J R. Kimmel, M.D. Robbins, and R.N. Zare, J. Amer. Soc. Mass Spectrom.18, 1888–1901 (2005).
BTEX Benzene, toluene, ethylbenzene, and xylene
C Cation
CA Collisional activation
CAD Collisionally activated decomposition
CAF Chemically assisted fragmentation
CCA α-Cyano-4-hydroxycinnamic acid (a MALDI matrix)
CDEM Continuous-dynode electron multiplier
CDNT Conformation-dependent neutralization theory
Mass spectrometry now deals with high molecular mass, highly charged ions of complex structures. The reactions and structures of these ions is a matter of experimental interrogation as well as theoretical modeling. The authors discuss the CDNT theory in this paper and its applicability in determination of the charge state distribution for folded proteins in the gas phase. See: V.J. Nesatyy and M.J.-F. Suter, J. Mass Spectrom. 39, 93 (2004).
CE Charge exchange; Collision energy; Capillary electrophoresis
CEC Consolidated Electric Corporation (a former MS manufacturer)
CEMA Channel electron-multiplierarray
cf Conflat™
CFFAB Continuous-flow fast atom bombardment
CFP Continuous flow probe
CHCA Cyano-4-hydroxycinnamic acid (a MALDI matrix)
CI Chemical ionization
CID Collision-induced dissociation
CIDI Collisionally induced dissociative ionization
CIT Cylindrical ion trap
CM Center-of-mass
CMD Carbohydrate membrane desalter
CNL Constant neutral loss
CODA Component detection algorithm
COM Center-of-mass
COMSPARI Comparison of spectral retention information
CREMS Charge-reduction electrospray mass spectrometry
CRM Charged residue model
CS Charge stripping
CV Compensation voltage
CX Charge exchange
CXP Collision-cell exit potential
CZE–MS Capillary zone electrophoresis mass spec
D Disproportionation factor, Deuterium
Da Daltons
DA Dopant-assisted
DAC Digital-to-analog converter
DADI Direct analysis of daughter ions
DAPCI Desorption atmospheric pressure chemical ionization
DAR Data-acquisition routine
DART Direct analysis in real time
DB Database
dbe Double-bond equivalent
DCI Desorption (or direct) chemical ionization
DCT Double charge transfer
DCTB trans -2-[3-{4-tert-Butylphenyl}-2-methyl-2-propenylidene]malononitrile (a MALDI matrix)
DE Delayed extraction
DEI Desorption (or direct) electron ionization
DESI Desorption electrospray ionization
DESI is an ambient-pressure sampling method in which an electrospray ionization tip is used to generate charged droplets that impact a condensed phase surface that contains the sample. The vapors that leave the surface reflect the incident sample droplets as well as the surface composition of the condensed phase sample. The mechanisms of the total procss are complex, but two characteristics underscore the usefulness of the method: the high sensitivity of the subsequent mass spectrometric analysis and the ease with which a multitude of different samples can be accommodated. See: Z. Takáts, J.M. Wiseman, and R.G. Cooks, J. Mass Spectrom.40, 1261–1275 (2005).
DF Double focusing
DFTPP Decafluorotriphenylphos-phine
DHB 2,5-Dihydroxybenzoic acid (a MALDI matrix)
DI Desorption ionization
DIN Direct injection nebulizer
DIOSMS Desorption ionization on silicon mass spectrometry
DIP Direct-insertion probe
DLI Direct liquid introduction
DLV Direct laser vaporization
DNFW Latin for "Please do not mess with the instrument"
DP Direct probe; Declustering potential; Diffusion pump
DPBD Diphenyl butadiene (a MALDI matrix)
DS Data system
DTIMS Drift-tube ion mobility spec
E Energy; Electric sector
EA Electron affinity
EAD Electron avalanche desorption
ECD Electron-capture dissociation
ECID Electron-capture-induced dissociation
ECMS Electron-capture mass spec
ECNCI Electron-capture negative chemical ionization
ECNI Electron-capture negative ionization
ECP Emitter-current programmer
EDD Energy-distribution difference
EE Even-electron ion
EED Electron excitation dissociation
EHI Electrohydrodynamic ionization
EI Electron ionization, Electron impact
EIEIO Electron-induced excitation of ions from organics
EIS External ion source
EJMSEuropean Journal of Mass Spectrometry
EM Electron multiplier
EMP Electron multiplier
EOID Electrooptical ion detector
EP Entrance potential
ERMS Energy-resolved mass spectrometry
ES Electrospray; Electrospray ionization
ESA Electrostatic analyzer
ESCI Combined electrospray and atmospheric pressure ionization source
ESI Electrospray ionization
ESP Electrospray ionization
ESPI Electrospray ionization
esu Electrostatic unit
ET Electron transfer
ETD Electron-transfer dissociation
Electron-capture dissociation has proven useful in the sequence analysis of peptide ions stored in a Fourier-transform instrument in which the peptide ions interact with a population of thermal electrons. However, a quadrupole ion trap, also a common instrument used for these analyses, will not store the thermal electrons. An anionic carrier is therefore used to transfer an electron in a low-energy collision with the positive peptide ions, and initiate the electron-induced nonergodic dissociation. See: J.E.P. Syka, J.J. Coon, M.J. Schroeder, J. Shabanowitz, and D.F. Hunt, Proc. Nat. Acad. Sci. USA 101, 9528–9533 (2004).
ETV Electrothermal vaporization
eV Electron volt
FA Flowing afterglow; Ferulic acid (a MALDI matrix)
FAB Fast-atom bombardment
FAIMS High Field Asymmetric Waveform Ion Mobility Spectrometry
FAME Fatty acid methyl ester
FC Faraday cup
FD Field desorption
FFID Fission-fragment-induced desorption
FFR Field-free region
FI Field ionization
FIA Flow-injection analysis
FIB Fast-ion bombardment
FIK Field ionization kinetics
FIMS Field-ionization mass spectrometry
FNB Fast-neutral beam
FRET Fluorescence resonance energy transfer
FRET is the study of changes in measured fluorescence intensity from molecules as a function of their three-dimensional conformation. It has been used to study conformations in the cellular condensed phase, and more recently for gas phase ions in an FTMS system. These ions have been tagged with the appropriate donors, acceptors, and quenchers, and the changes in fluorescence used as a molecular ruler. See: M. Dashtiev, V. Azov, V. Frankevich, L. Scharfenberg, and R. Zenobi, J. Amer. Soc. Mass Spectrom.16, 1481–1497 (2005).
FTICR Fourier transform ion cyclotron resonance
FTMS Fourier transform mass spectrometry
FT-TOF Fourier transform-time-of-flight mass spectrometry
FWHH Full width at half height
FWHM Full width at half maximum
G Multiplier gain; Glycerol (an LSIMS matrix)
GC Gas chromatography
GC–MS Gas chromatography–mass spectrometry
GDMS Glow discharge mass spectrometry
GIANT Gas-phase ion and neutral thermochemistry (a published compilation of such data)
GLP Good laboratory practice
GPC Gel permeation chromatography
HABA 2-(4-Hydroxyphenylazo) benzoic acid (a MALDI matrix)
HASTE High-amplitude short-time excitation
The operation of a quadrupole ion trap mass spectrometer for MS-MS requires that ions be excited by collision with a neutral target gas so that dissociation occurs, but that all of the ions so formed be retained within the trap so that the resultant mass spectrum can be accurately measured. The discordant goals of excitation and trapping are compromised in the usual electronic operation of an ion trap, with a longer excitation leading to loss of lower-mass ions in the MS-MS spectrum. Recent work involves the use of a higher amplitude and shorter duration excitation function. Extra credit goes to an acronym with a true mnemonic significance. See: C. Cunningham, Jr., G.L. Glish, and D.J. Burinsky, J. Amer. Soc. Mass Spectrom. 17, 81–84 (2006).
4-HBSA 4-Hydroxybenzenesulfonic acid (an LSIMS matrix)
HCCA α-Cyano-4-hydroxycinnamic acid (a MALDI matrix)
HCD Heated capillary dissociation
HCP Hollow cathode plume
H/D Hydrogen/deuterium
HDX Hydrogen/deuterium exchange
HE High energy
HECD Hot electron capture dissociation
2-HEDS 2-Hydroxyethyl disulfide (an LSIMS matrix)
HMM High molecular mass
HPA 3-Hydroxypicolinic acid (a MALDI matrix)
2-HEPA 2-Hydroxyphenethyl alcohol (an LSIMS matrix)
HPMS High-pressure mass spectrometer
HRMS High-resolution mass spectrometry
HSI Hyperthermal surface ionization
HSMS Headspace mass spec
HT Hadamard transform; High tension, which is a Britishism for HV (high voltage)
HTMS High temperature mass spectrometry
HT-TOF-MS Hadamard-transform time-of-flight mass spectrometry
HV High voltage
HXMS Hydrogen/deuterium exchange mass spectrometry
IAA Indole acrylic acid (a MALDI matrix)
IC Ion chromatography
ICAT Isotope-coded affinity tag
ICDR Ion cyclotron double resonance
ICEMS Ion-pair liquid chromatography electrospray ionization mass spectrometry
IC–MS Ion chromatography–mass spectrometry
ICP–MS Inductively coupled plasma-mass spectrometry
ICR Ion cyclotron resonance
IDMS Isotope dilution mass spectrometry
IE Ionization energy; Ionizing energy; Ion evaporation
IELC Ion exchange liquid chromatography
IJMSIP International Journal of Mass Spectrometry and Ion Physics (Volumes 1–62)
International Journal of Mass Spectrometry and Ion Processes (after Volume 62)
IJMS International Journal of Mass Spectrometry
IKE(S) Ion kinetic energy (spectrometry)
IMAC Immobilized metal affinity chromatography
IP Ionization potential
IPD Ion-photon detector
IRMPD Infrared multiphoton dissociation
IRMPD in MALDI was used in conjunction with CID and ESI, along with HDX studies and computational simulations (illustrating the power of acronym-shorthand), to study the gas-phase fragmentation of 2-hydroxybenzyl-N-pyridinylamine derivatives. The comprehensive work allowed a comparison to both the classical solution mechanism as well as the proposed unique gas-phase fragmentation. See: H.-Y. Wang, X. Zhang, Y.-L. Guo, and L. Lu, J. Am. Soc. Mass Spectrom.16, 1561–1573 (2005).
IRMS Isotope ratio mass spectrometry
ISD In-source decay
ISP Ionspray
ISR Ion/surface reaction
ITD™ Ion trap detector
ITMS Ion trap mass spectrometry
ITPMS Isotacophoresis mass spectrometry
IUPAC International Union of Pure and Applied Chemistry
JASMS Journal of the American Society for Mass Spectrometry
JEOL Japan Electro-Optics Laboratory
JMS Journal of Mass Spectrometry
K Kelvin
KCMS Knudsen cell mass spectrometry
kDa Kilodalton
KERD Kinetic energy release distribution
K+IDS Potassium ion desorption spectrometry
KM Kinetic method
KNN K-nearest neighbor
L Length of flight tube
LAMMA™ Laser microprobe mass analyzer
LAMPAS Laser mass analyzer for particles in the airborne state
LBO Light beam oscillograph
LC–MS Liquid chromatography –mass spectrometry
LD Laser desorption
LDI Laser desorption ionization
LDLP Laser desorption/laser photoionization
LE Low energy
LI Liquid ionization
LIMA™ Laser ionization mass analyzer; Laser ion microprobe analyzer
LIT Linear ion trap
LMCO Low mass cut-off
LMM Low molecular mass
LMMS Laser microprobe mass spectrometer
LMS Laser mass spectrometry
LMW Low molecular weight
LOD Limit of detection
Look here for an excellent overview of establishing the fitness for purpose of mass spectrometric methods. This publication includes essential definitions and discussions of analytically important terms such as the limit of detection. See: R. Bethem, J. Boison, J. Gale, D. Heller, S. Lehotay, J. Loo, S. Musser, P. Price, and S. Stein, J. Am. Soc. Mass Spectrom. 14(5), 528 (2003).
LOQ Limit of quantification
LRB Laboratory reagent blank
LSIMS Liquid matrix secondary ion mass spectrometry
LTOF Laser time-of-flight; Linear time-of-flight
LV/EI Low voltage electron ionization
m Mass of the ion in units of u
M/A Matrix/analyte ratio
Matrix-assisted laser desorption ionization mass spectrometry is dependent upon the admixture of sample with an energy-absorbing matrix. The existence of the matrix effect is central, and studies of how it is manifest are particular interesting. In this publication, the effect of changing matrix-to-analyte ratios on the mass distribution of ions in a standard polymeric mixture is explored. See: A.J. Jaber, J. Kaufman, R. Liyanage, E. Akhemotova, A. Marney, and C.L. Wilkins, J. Am. Soc. Mass Spectrom. 16, 1772–1780 (2005).
MAGIC Monodisperse aerosol generator interface to chromatography
MALD Matrix-assisted laser desorption
MALDI Matrix-assisted laser desorption ionization
MAPS Method for analyzing patterns in spectra
MB Molecular beam
MBMS Molecular beam mass spectrometry
MCA Multichannel analyzer
MCI Massive cluster impact
MCMS Midwest Center for Mass Spectrometry
MCP Microchannel plate (detector)
MCPD Microchannel plate detector
MEND Matched filtration with experimental noise determination
MDMS Microdialysis mass spectrometry
MDL Method detection limit
MESIMS Matrix-enhanced secondary ion mass spec
Hanton and Owens report research using some common MALDI matrices for preparation of polymer samples analyzed by secondary ion mass spectrometry, using polmers in the mass distribution range of 1000–4000 Da to record MESIMS spectra and compare them to MALDI mass spectra. The concept of matrix-assisted SIMS precedes MALDI, dating to the early 1980s. See: S.D. Hanton and K.G. Owens. J. Am. Soc. Mass Spectrom. 16, 1172–1180 (2005).
MI Metastable ion
MID Multiple ion detection
MIKE(S) Mass-analyzed ion kinetic energy (spectrometry)
MIM Multiple ion monitoring
MIMS Membrane introduction mass spectrometry
MIP Microwave-induced plasma
MNBA meta-Nitrobenzyl alcohol, an LSIMS matrix
MNDO Modified neglect of differential overlap
MO Molecular orbital
MOWSE Molecular weight search
One of the first publications that described this program appeared in 1993. This work showed that proteins can be identified uniquely by match of as few as three accurately determined masses for peptides when those masses are found in a large database that contains accurate masses and proteins that give rise to them. As the number of possibilities rise, so does the need for additional accurate masses; the relationship is a classic study in bioinformatics. See: D.J.C. Pappin, P. Hojrup, and A.J. Bleasby, Curr. Biol. 3(6), 327–332 (1993).
MPD Multiphoton dissociation
MPI Multiphoton ionization
MPM Multiple peak monitoring
MQDT Multichannel quantum defect theory
MRM Multiple reaction monitoring
MSn If n = 2, MS-MS. If n = 3, MS-MS-MS. Repeat as necessary.
MSB Mass Spectrometry Bulletin
MSD Mass-selective detector
MSDC Mass Spectrometry Data Center
MSM Multiple scattering method
MSR Mass Spectrometry Reviews
MS-MS Mass spectrometry-mass spec
MSSS Mass spectral search system
MULTUMMultiturn mass spectrometer
A multiturn time-of-flight mass spectrometer has been used to achieve high mass resolution for ions generated by MALDI by multiple passages of the ion through the flight tube. A sophisticated ion injection and timing scheme must be used to accomplish this feat, but the authors demonstrate feasibility and impressive results. See: D. Okumura, M. Toyoda, M. Ishihara, and I. Katakuse, J. Mass Spectrom. 39, 86 (2004).
MW Molecular weight
Mwt Molecular weight
m/z Mass-to-charge ratio
N Neutral molecule or species
NBA meta-Nitrobenzyl alcohol (an LSIMS matrix)
NCBI National Center for Biotechnology Information
NCE Normalized collision energy
NCI Negative ion chemical ionization
NET Normalized elution time
NI Negative ion
NICI Negative ion chemical ionization
NOBA meta-Nitrobenzyl alcohol (an LSIMS matrix)
+NR+ Neutralization reionization; a positive ion is neutralized and then reionized
NRMS Neutralization reionization mass spectrometry
NSI Nanospray ionization
o Orthogonal
oa Orthogonal acceleration
ODN Oligodeoxynucleotide
OE Odd-electron ion
OMS Organic Mass Spectrometry
oTOF Orthogonal (source) time-of-flight
PA Proton affinity
PAD Post-acceleration detector
PAI Post-ablation ionization
PALMS Particle analysis by laser mass spectrometry
PBM Probability-based matching
PBMS Particle-beam mass spectrometry
PCA Principal component analysis
PCI Positive ion chemicalionization
PCR Polymerase chain reaction
The polymerase chain reaction is used to amplify sequences, and the products are often later analyzed by a combination of chromatography and mass spectrometry. Commercial PCR products contain components that can ultimately affect the quality of the mass spectral data through complex matrix effects. Analytical results using different commercial products and some general guidelines for the analysis of genomic DNA are described in a recent publication. See: H. Oberarcher, H. Niederstätter, B. Casetta, and W. Parson, J. Am. Soc. Mass Spectrom. 17, 124–129 (2006).
PD Plasma desorption; Photodissociation
PDF Pulsed dynamic focusing
PDMS Plasma desorption mass spectrometry
PEPICO Photoelectron-photoion coincidence spectroscopy
PES Photoelectron spectroscopy
PFK Perfluorokerosene
PFTBA Perfluorotributylamine
PHD Pulse height distribution
PHT Peptide hits technique
PI Positive ion
PID Particle-induced desorption; Photon-induced dissociation
PIE Photoionization efficiency
PIT Protein-identification technology
PIT-MS Proton-transfer ion-trap mass spectrometry
PIPECO Photoion-photoelectron coincidence spectroscopy
PLE Pressurized liquid extraction
PMF Peptide mass fingerprinting
PMM Peptide mass maps
PMS Parallel mass spectrometry
PPINICI™ Pulsed positive ion negative ion chemical ionization
PSD Postsource decay
PSI Pulsed sample introduction
PSM Peptide–spectrum match
PSPF Postsource pulse focusing
PTM Post-translational modification
PTR Proton-transfer reaction
PyMS Pyrolysis mass spectrometry
q Quadrupole device used in rf-only mode as a collision cell
Q Quadrupole mass filter
Q Reaction endothermicity
QA Quality assurance
QC Quality control
qCID Collision-induced dissociation accomplished within an rf-only quadrupole
QCPE Quantum Chemistry Program Exchange
QET Quasi-equilibrium theory
QFTMS Quadrupole Fourier-transform mass spectrometry
QIT Quadrupole ion trap
QLT Quadrupole linear ion trap
QTOF Quadrupole followed by a time-of-flight mass analyzer
QUISTOR Quadrupole ion storage trap
r Radius of electric or magnetic sector
RA Relative abundance; all-trans-retinoic acid (a MALDI matrix)
RCM Rapid Communications in Mass Spectrometry
rdbe Rings plus double bonds equivalent
REMPI Resonance-enhanced multiphoton ionization
RF Radio frequency; Response factors
RGA Residual gas analyzer
RI Relative intensity
RIMS Resonance-ionization mass spectrometry
RiT Rectilinear ion trap
Recent works examine boundary and resonance ejection phenomena in an RIT as a means to characterize higher order factors that affect the performance of the mass analyzer. See: Z. Ouyang, G.X. Wu, Y.S. Song, H.Y. Li, W.R. Plass, and R.G. Cooks, Anal. Chem. 76(16), 4595–4605 (2004); and A.M. Tabert, M.P. Goodwin, and R.G. Cooks, J. Am. Soc. Mass Spectrom.17, 56–59 (2004).
RLCT Rayleigh limiting charge theory
RN Resonance neutralization
ROOMS Regular old ordinary mass spectrometry (courtesy of R.A. Hites)
R2PI Resonant 2-photon ionization
RP Resolving power
RPD Retarding potential difference
RPLC Reversed-phase liquid chromatography
RRKM Rice, Ramsperger, Kassel, and Marcus
RSMS Rapid single particle mass spectrometer
rTOF Reflectron time-of-flight
SA Sinapinic acid (a MALDI matrix)
SCMSS Sanibel Conference on Mass Spectrometry
SCX Strong cation exchange
SDM Selected dissociation monitoring
SEAC Surface-enhanced affinity capture
SEC Size-exclusion chromatography
SELDI Surface-enhanced laser desorption ionization
SEND Surface-enhanced neat desorption
SFC-MS Supercritical fluid chromatography–mass spectrometry
SFE Supercritical fluid extraction
SI Spray ionization; Surface ionization
SID Surface-induced dissociation
SIFDT Selected-ion flow drift tube
SIFT Selected-ion flow tube
SILVER Spectrum intensity likelihood viewer
SILVER is a mass spectrum viewer program that displays the results of matching algorithms and probabilistic based scoring routines in such a way that facilitates a final decision by a person actually evaluating the data. See F.D. Gibbons, J.E. Elias, S.P. Gygi, and F.P. Roth, J. Am. Soc. Mass Spectrom. 15, 910–912 (2004).
SIM Selected-ion monitoring
SIMBROC Simulated background and reduction–oxidation calculations
SIMS Secondary ion mass spectrometry
SIN Surface-induced neutralization
SIOMS Surface ionization organic mass spectrometry
SIR Selected-ion recording
SMB Supersonic molecular beam
SMOKE Stored modulation of kinetic energy
SMOW Standard mean ocean water
S/N Signal-to-noise ratio
SOMO Singly occupied molecular orbital
SPE Solid-phase extraction
SPME Solid-phase micro extraction
SRBC Simulated reduction and background calculations
SRM Selected reaction monitoring; Standard reference material
SSIMS Static secondary-ion mass spectrometry
SSMS Spark source mass spec
STIRS Selftraining interpretive and retrieval system
STMT Stieltjes–Tchebycheff moment theory
SWIFT Stored-waveform inverse Fourier transform
SWIM Stored waveform ion modulation
t Ion flight time; Time
T Tesla
TAC Time-to-amplitude converter
TAMS Tandem accelerator mass spectrometry
TDC Time-to-digital converter
TEL Translational energy loss
TEPSICO Threshold electron photoion secondary ion coincidence
TES Translational energy spectroscopy
TGAMS Thermogravimetric analysis mass spectrometry
TG GC–MS Thermogravimetry gas chromatography–mass spectrometry
TI Thermal ionization
TIC Total ion current
TID Trapped-ion detector; Thermally-induced dissociation
TIMS Thermal-ionization mass spectrometry
TISI Turbo ion-spray ionization
TIP True isotopic pattern (trademark)
TLC-MS Thin layer chromatography–mass spectrometry
TMS Trimethylsilyl; Tandem mass spectrometry; Thermospray mass spectrometry
ToF Time-of-flight
TOF Time-of-flight
TOFMS Time-of-flight mass spectrometry
TQ Triple quadrupole
TQMS Triple-quadrupole mass spectrometry
TRPD Time-resolved photodissociation
TSP Thermospray
TSQ™ Triple stage quadrupole
u mass unit (1/12 of the mass of 12 C), now replaced by dalton
UVLD Ultraviolet laser desorption
UVPD Ultraviolet photodissociation
v ion velocity
V Accelerating voltage
VG Vacuum Generators, former name of a manufacturer of mass spectrometers
VOC Volatile organic compound
VTST Variational transition state theory
W Wien filter
z charge state of the ion in units of the electric charge
ZPE Zero-point energy
Detecting Cancer Biomarkers in Canines: An Interview with Landulfo Silveira Jr.
November 5th 2024Spectroscopy sat down with Landulfo Silveira Jr. of Universidade Anhembi Morumbi-UAM and Center for Innovation, Technology and Education-CITÉ (São Paulo, Brazil) to talk about his team’s latest research using Raman spectroscopy to detect biomarkers of cancer in canine sera.