An inexpensive fiberoptic-based formaldehyde field sensor is described for monitoring low-levels of formaldehyde, a widespread indoor air pollutant, based on the principle of evanescent wave absorption of light. Sensor prototypes following that principle are being tested in two plywood board production plants.
A simple colorimetric and fluorescent dual-channel chemosensor was designed and synthesized to identify Hg2+ in an aqueous solution with demonstrated high selectivity and sensitivity.
Spectroscopic ellipsometry, correlated with UV-vis-NIR spectroscopy, is used to determine the optical constants of thin films, such as in GexSb40-xSe60 chalcogenide glass.
This study shows that surface-enhanced Raman spectroscopy (SERS) of serum can provide an experimental basis for diagnosing leukemia in patients.
DNA effectively removes chrysene from contaminated water through intercalation, as confirmed by various analytical methods, offering a potential novel approach for chrysene elimination in water pollution.
The purpose of this work is to achieve rapid and nondestructive determination of tilapia fillets storage time associated with its freshness. Here, we investigated the potential of hyperspectral imaging (HSI) combined with a convolutional neural network (CNN) in the visible and near-infrared region (vis-NIR or VNIR, 397−1003 nm) and the shortwave near-infrared region (SWNIR or SWIR, 935−1720 nm) for determining tilapia fillets freshness.
Those inexperienced in using FT-IR spectrometers can encounter problems when measuring spectra. This article discusses several main issues that most users experience while using FT-IR spectrometers and how to remedy each problem.
Traditional qualitative analysis of agricultural materials using near-infrared spectroscopy can be improved using information-based classification methods, such as projection based on principal components and the Fisher criterion (PPF).
Of the 78 million tons of plastic packaging manufactured every year, approximately one-third ends up in the ocean, the air, and most foods and beverages. To monitor the proliferation of these plastics, an ultrasonic capture method is demonstrated that produces a 1500-fold enhancement of Raman signals of microplastics in water.
Portable X-ray fluorescence was used to analyze the archaeological remains of an Underground Railroad station to gain a clearer understanding of the construction phases it underwent during the 19th century.
Detecting metal elements in liquid samples cannot be done efficiently by only using LIBS, but when the technique is combined with appropriate membrane materials, rapid analysis of solution samples can be realized.
The significance of the smaller spectral region of the Raman spectrum, defined as the “fingerprint in the fingerprint” region, cannot be overstated when it comes to active pharmaceutical ingredient identity testing (API).
A look at two ICH draft publications reveals that the EWG has much revision work to do for these publications to fully cover the validation lifecycle process.
Inline FT-NIR and offline terahertz Raman imaging analysis are used to characterize active pharmaceutical ingredient (API) crystallinity and to monitor different solid physical states of the API, to control process parameters of hot melt extrusion.
The study developed an effective mid-infrared spectroscopic identification model, combining principal component analysis (PCA) and support vector machine (SVM), to accurately determine the geographical origin of five types of millet with a recognition accuracy of up to 99.2% for the training set and 98.3% for the prediction set.
The utility of the GladiATR diamond ATR, modified with an internal liquid light guide to illuminate the sample from underneath the ATR element, was explored to analyze the photo-polymerization of carbitol acrylate at 405 nm using 1 wt% TPO.
Measurements of the optical proper ties of a ceramic material, Z93, which is in current use on the International Space Station (ISS), reveal why this material is successful for thermal control in the ISS implementation, and also point to potential future material design improvements.
Size-exclusion chromatography (SEC), with the use of ammonium acetate buffer, can be coupled on-line to electrospray ionization MS for the characterization of size variants of therapeutic monoclonal antibodies (mAbs). A quadrupole time-of-flight (QTOF) MS system was employed, and the MS method was optimized to achieve favorable sensitivity for high-mass detection, while maintaining the structural integrity of the aggregates (or high molecular weight species) and fragments (or low molecular weight species).
In this article, tunable diode laser absorption spectroscopy (TDLAS) is used to measure ammonia leakage, where a new denoising method combining empirical mode decomposition with the Savitzky-Golay smoothing algorithm (EMD-SG) is proposed to improve the signal-to-noise ratio (SNR) of absorbance signals.
Long chain fatty acids (LCFAs) function as a source of metabolic energy, substrates for membrane biogenesis, and storage of metabolic energy. Oxylipins, oxygenated derivatives of LCFAs, regulate the activity of many cellular processes. Existing methods for the analysis of LCFAs and oxylipins have limited compound coverage and sensitivity that, therefore, prevent their application in biological studies. In this work, we developed a high-throughput LC–MS method for analysis of 51 LCFAs and oxylipins. LCFAs and oxylipins were first extracted from biological samples via solid-phase extraction. The extracted molecules were analyzed by targeted comparative metabolomics. Saturated and monounsaturated LCFAs were analyzed in single ion reaction mode, while polyunsaturated LCFAs and oxylipins were analyzed in multiple reaction monitoring mode. Using this method, we successfully quantified 31 LCFAs and oxylipins from mouse livers.
In X-ray fluorescence (XRF) analysis, physical traceability chains are used to quantify the absolute elemental content in a sample. The physical traceability chain relies on absolute knowledge of the X-ray spectral distribution used for the excitation of the instrument and is currently used at synchrotron radiation facilities. Here, we discuss the transfer of the physical traceability chain to laboratory-based X-ray sources, which are often polychromatic, with the view to generate wider application of quantitative XRF analysis.
In this study, in situ Raman spectroscopy was used to detect the formation, growth, and evolution of corrosion inside a salt fog chamber. These results pave the way for monitoring the real-time observation of corrosion on metal surfaces.
Wednesday, October 6, 2021 at 11am EDT| 8am PDT| 4pm BST| 5pm CEST Join this webcast to hear about the latest trends in tracking product authenticity, for food and other consumer products, and learn how to overcome challenges in isotopic ratio analysis with quadrupole ICP-MS.
Drug discovery using high-throughput screening of discreet compounds, and the discovery of natural products with pharmacological mechanisms of action, rely on bioassay-guided fractionation analysis. Recent applications of affinity selection–mass spectrometry (AS-MS) are useful for exploring the discovery of ligands to membrane-bound proteins and RNA targets.
Glutathione (GSH) is an intracellular thiol that plays a major role in biological systems. Therefore, the development of effective probes that can detect GSH elicits significant attention.
By using green synthesized AgNPs modified by chitosan and organic acid, a simple, cost-effective, and highly selective onsite colorimetric detection method for Pd2+ and Hg2+ ions was developed.
This study examines the fluorescence enhancement effects of forsythoside E, one of metabolites of Forsythia suspensa, on human serum albumin (HSA) and bovine serum albumin (BSA) under simulated physiological conditions.
IR absorption spectroscopy technology can solve the problem of line aliasing in gas detection. Here, continuous wavelet transform was used in time-frequency analysis to improve spectral component identification and quantitative detection of gases.